Blood Sugar Converter

Blood sugar converter: switch glucose readings between mg/dL and mmol/L instantly, with a quick reference chart. Free, private, runs locally, no signup.

Updates automatically as you type.

Calculated in your browser; your inputs are not sent to us. Privacy

Results will appear here.

General estimate for planning only — not medical advice. Consult a doctor about your specific situation.

Calculation details
Every figure above is calculated locally in your browser from the assumptions shown. No inputs are sent anywhere. See the methodology section below for how this tool works.
Use this resultShare the current inputs, or ask ChatGPT to explain the calculation in context.
Ask an AI to explain this result
Share this result

Review the generated output before relying on it.

This tool runs in your browser. Your calculator inputs and results are never transmitted to us or to ad/affiliate partners. Ads and sponsored links may set third-party cookies to serve and measure them, but they never receive your calculation values. If you explicitly save a scenario, its permitted fields stay in local browser storage until you clear them. See our Privacy Policy.

Use this result

Share the current inputs or ask ChatGPT to explain the calculation in context.

More options
Report a calculation issue
Glucose thresholds in mg/dL and mmol/L side by side
The same fasting band is 70 to 99 mg/dL, or 3.9 to 5.5 mmol/L.
Method & verification

How This Tool Works

fact-checked against our calculation methodology

Calculation Method

Computes Converted from Glucose value and Unit.

Site methodology

No unrelated authority link is added merely to make this page look sourced. Tool-specific external sources are shown only when they directly support the method, rate, or rule.

Assumptions to Verify

  • These tools provide general estimates for planning and education only.
  • They are not medical advice and not a substitute for a qualified healthcare professional.
  • Always consult your doctor or another healthcare provider about your specific situation.

Privacy: The calculation runs in this browser. Shared links contain the page address only, not your inputs or results.

Worked examples both directions

Say a lab report lists 5.5 mmol/L and your US meter shows mg/dL. Multiply: 5.5 x 18.0182 = 99.0999, which rounds to 99 mg/dL. Now reverse it: a fasting reading of 108 mg/dL divided by 18.0182 gives 5.9940, which displays as 6.0 mmol/L. Notice the rounding gap: the exact pair for 6.0 mmol/L is 108.1 mg/dL, so a 108 mg/dL reading converts back to 5.99, not a clean 6.0. That one-decimal wobble is normal, not an error.

The factor itself comes from chemistry, not convention. Glucose has a molar mass of about 180.16 g/mol, and one liter equals 100 mL, so 1 mmol of glucose per liter weighs 180.16 mg per liter. The standard clinical conversion is 18.016, and the tighter 18.0182 used here reflects the IUPAC atomic weights for C (12.011), H (1.008), and O (15.999): 12.011 x 6 + 1.008 x 12 + 15.999 x 6 = 180.156. Some US consumer meters still ship with a coarse factor of 18, which is why 100 mg/dL may show as 5.6 mmol/L on one device and 5.5 on another. The difference peaks around 0.3 mmol/L at a reading of 250 mg/dL: 250 / 18 = 13.9, while 250 / 18.0182 = 13.87, both rounding to 13.9 but diverging by one decimal on nearby inputs.

Where the conversion quietly misleads

The number converts cleanly, the context does not. A fasting target of 70 to 99 mg/dL equals 3.9 to 5.5 mmol/L, but the 2-hour post-meal threshold differs by guideline set: under 140 mg/dL (7.8 mmol/L) in most ADA material versus under 155 mg/dL (8.6 mmol/L) on some EU lab reports. Converting a value without the matching threshold band invites a false alarm either way, so always convert the reference range alongside the reading.

Three edge cases distort results more than the 0.01% factor precision ever will. First, whole-blood meters read roughly 10 to 15 percent lower than plasma lab values at the same true glucose; a 100 mg/dL whole-blood reading corresponds to about 110 to 115 mg/dL plasma, and most modern meters now report plasma-equivalent but some older strips do not. Second, HbA1c converts differently: 5.7 percent is about 39 mmol/mol under the IFCC unit, a completely separate scale from the 18.0182 factor, and mixing the two is a common error. Third, diluted or hemolyzed samples, and readings taken over 200 mg/dL on some older meters, can carry error margins near 15 percent, which dwarfs any rounding difference. A converted value is exactly as accurate as the input meter, no more.